Question How to activate/de-activate passage mode in E-Plex 2000 and PowerPlex 2000 Series? |
Answer You have already programmed a default duration for a door to remain in Passage Mode. When you enable Passage Mode, it becomes enabled for the duration you have set in Procedure 5 - Program the Duration of the Passage Mode period. The duration feature is not available on PowerPlex 2000 models. If your length is 6 hours, and you enable Passage Mode at 1:00, it will automatically re-lock at 7:00. Even if the lock was taken in and out of Passage Mode multiple times during the six hour period, it will still re-lock after six hours (programmable) from the original starting period. This ensures that a lock will never remain in Passage Mode beyond the programmed time period. Required User Level: Master, Manager R-1 Put the lock into Pushbutton Programming Mode. R-2 Enter Command 399# to activate / de-activate Passage Mode. R-3 Enter the code where 1 = activate Passage Mode and 0 = de-activate Passage Mode. R-4 Example of Complete Entry to activate Passage Mode 399#1#. R-5 Enter another # to indicate the end of programming. R-6 You have now activated Passage Mode on the door. |