The following are descriptions of tools and settings specific to E-Plex/PowerPlex 2000 locks:
Transaction Report
A Transaction Report can be generated by pulling audits from the lock using the IrDA Adapter kit.
The "Audit Filter Information" sliders on the lock "Settings" tab can be used to configure what information is included in the report.
Note: Before attempting to run a Transaction Report for your E-Plex/PowerPlex 2000 lock, you must do the following:
Enable IrDA Infrared in Windows. See procedure below.
- Install the ACTiSYS IrDA Infrared dongle's drivers (available on the ACTiSYS website).
- Once the drivers are installed, the green LED on the dongle should illuminate when the device is plugged into your computer.
- The dongle should also appear in your list of devices in Windows Device Manager.
- At the lock, you must enter your Master Code, then put the lock into Communication Mode.
- Enter #(Master PIN)#900#
- Connect your IrDA Adapter kit to your USB port, and point it at the E-Plex/PowerPlex 2000 lock.
- In LUNA software, click the "Transaction Report" button.
- Once the Transaction Report is generated, you can configure the layout, print the report, or choose to save the report in various formats (Excel, PDF, Word).
Diagnostics
This tool is used to view important diagnostic information about the lock. Once it has been downloaded from the lock, this information will automatically be copied to your clipboard.
Note: Before attempting to run Diagnostics on your E-Plex/PowerPlex 2000 lock, you must do the following:
- Enable IrDA Infrared in Windows. See procedure below.
- Install the ACTiSYS IrDA Infrared dongle's drivers (available on the ACTiSYS website).
- Once the drivers are installed, the green LED on the dongle should illuminate when the device is plugged into your computer.
- The dongle should also appear in your list of devices in Windows Device Manager.
- At the lock, you must enter your Master Code, then put the lock into Communication Mode.
- Enter #(Master PIN)#900#
- Connect your IrDA Adapter kit to your USB port, and point it at the E-Plex/PowerPlex 2000 lock.
- In LUNA software, click the "Diagnostics" button.
- A pop-up window will appear containing the downloaded diagnostics information.
IrDA Programming
The IrDA Programming button can be used to update lock and user settings on an E-Plex/PowerPlex 2000 lock.
Note: This includes all the latest changes to software settings as they appear on the "Settings" and "User Information" tabs (including the "Audit Filter Information"), so be sure to click the "Save" button before programming to ensure the latest changes and settings are sent to the lock.
Note: Before attempting to program your E-Plex/PowerPlex 2000 lock, you must do the following:
Enable IrDA Infrared in Windows. See procedure below.
- Install the ACTiSYS IrDA Infrared dongle's drivers (available on the ACTiSYS website).
- Once the drivers are installed, the green LED on the dongle should illuminate when the device is plugged into your computer.
- The dongle should also appear in your list of devices in Windows Device Manager.
- At the lock, you must enter your Master Code, then put the lock into Communication Mode.
- Enter #(Master PIN)#900#
- Connect your IrDA Adapter kit to your USB port, and point it at the E-Plex/PowerPlex 2000 lock.
- In the LUNA software, click the "IrDA Programming" button.
User Information
The user information tab is used to add and modify E-Plex/PowerPlex 2000 users.
- Enabled - click this checkbox to enable the corresponding user
- User Number - the specific/unique number corresponding to a given user (001-099)
PIN - Personal Identification Number, or the user's access code. The number of digits is dictated by the "PIN Length" setting
(Note: The PIN cannot be all zeros)
- User Name - a text field for putting in the user's name
- User Type - select from one of the available types:
- Manager - a manager can program all lock functions except:
- defining the Access User Code length
- modifying master user Access Code
- resetting to default value
- activating lockout mode
- adding/deleting/enabling/disabling a Manager user.
- The number of Managers is limited only by available user table space (99 maximum because one "000" is reserved for the Master Code.
- Access User - an Access User has the ability to open the lock. The number of Access Users is limited only by available user table space (99 maximum because one "000" is reserved for the Master Code.
- Service User - a user with an Access Code valid for a configurable period of time. This period of time ("Hours of Activation") starts on the first use of the code. Each Service User combination is automatically deleted after its period of time expires. The number of Service Users is limited only by available user table space (99 maximum because one "000" is reserved for the Master Code.
- Manager - a manager can program all lock functions except:
- Hours of Activation - This is for Service Users only; this is the period of time for which a Service User PIN (access code) will be valid.
- This period of time starts on the first use of the code.
- Each Service User combination is automatically deleted after its period of time expires.
- Override Privacy - Click this checkbox to override the Privacy lock setting.