Question How to program the duration of the passage mode period in E-Plex 2000? |
Answer PROGRAM THE DURATION OF THE PASSAGE MODE PERIOD The length of time that the lock remains in Passage Mode is programmable on all models except PowerPlex 2000 versions. The factory default length of time for Passage Mode is 9 hours - you may leave the default. Once the lock has been put into Passage Mode, it will automatically relock after the designated duration. Required User Level: Master, Manager D-1 Put the lock into Pushbutton Programming Mode. D-2 Enter command code 005#. D-3 Then TT#, where TT= 01 to 24 hours. D-4 A TT entry of 00 means there is no time limit - the door remains unlocked. D-5 Enter 005 #TT#; for example, 005#06# for six hours. D-6 Example of Complete Entry: 005#06#. D-7 Enter another # to indicate the end of programming. D-8 In this example, the lock will remain unlocked for six hours, starting from the time you put it in D-9 You have now configured the duration of the Passage Mode period for that lock. This does NOT D-10 The new length of time will take effect the next time you put a lock into Passage Mode by |