Visual Feedback Message Definitions for E-Plex 50xx/30xx Series
| Condition | Parameters | |||
| Green LED | Red LED | Duration | Rate | |
| Valid pushbutton pressed | ON | OFF | 1/10 sec | Once |
| Keypad Timeout expired | OFF | ON | 1 sec | Once |
| Valid access code keyed | ON | OFF | 1 sec | Once |
| Access granted | ON | OFF | 1/10 sec | 1 sec; till end of unlock out time |
| Access granted (battery low condition) | ON | ON | 1/10 sec | 1 sec; till end of unlock out time |
| Access denied | OFF | ON | 1 sec | Once |
| Valid programming entry | ON | OFF | 1 sec | Once |
| Invalid programming entry (including duplicate access code | OFF | ON | 1 sec | Once |
| Tamper shutdown beginning | OFF | ON | 2 sec | Once |
| Tamper shutdown state | OFF | ON | 1 sec | 10 sec; till end of tamper shutdown time |
| Tamper shutdown ending | ON | OFF | 2 sec | Once |
| Communication starting | ON | OFF | 1 sec | Once |
| Communication ending | ON | OFF | 1 sec | Once |
| Communication aborted | OFF | ON | 1 sec | Once |
| Communication in progress | ON (Alternate) | ON (Alternate) | 1/10 sec | 1 sec; till end of communication with M-unit PDA |
| Lock model, feedback | On (Alternate) | On (Alternate) | 1/2 sec | Once |
| Deadbolt/Thumb turn Privacy Activated | OFF | On | 1 sec | Once |
| Deadbolt/Thumb turn Privacy De-activated | ON | OFF | 1 sec | Once |
| Hard reset sequence in progress | On (Alternate) | On (Alternate) | 1/2 sec | 1/2 sec; till end of next sequence |
| End of successful hard reset | ON | OFF | 2 sec | Once |
| End of unsuccessful hard reset | OFF | ON | 2 sec | Once |