Question How to activate Opening Delay and Confirmation Window via Combi B 90 PC Software? |
If this function is selected both values the Opening Delay and the Confirmation Window must be unequal to zero. Both values must be zero when this function shall not be activated. If the function OD/CW is activated and values for OD/CW were defined, those values are valid for the Master Code, Manager Code and all activated User Codes except for the Courier Code. The Courier Code can still open the lock. To activate the Opening Delay, the possible value to be defined is between 1 and 99 minutes. To activate the Confirmation Window, the possible value to be defined is between 1 and 19 minutes.
Setting date and time automatically It is possible to set the date and time of the lock automatically with the system time.
|