Paxos - Setting the Maximum Open Period
The function Maximum Open Period allows you to determine how long the door can remain open until a forced closure is triggered. As soon as the Maximum Open Period has elapsed, an intermittent beep sounds when the door locks are open until the system is secured (boltwork closes).
Maximum Open Period Details
- Setting range of Maximum Open Period [mm:ss]:
- 00:00 Maximum Open Period disabled
- 00:01 to 99:59 1 second to 99 minutes and 59 seconds - On delivery, the Maximum Open Period is disabled (setting “00:00”)
- The Maximum Open Period is available only in the settings for lock 1 and is valid for the entire locking system.
- The setting is taken over with the next opening only.
- The Maximum Open Period does not apply to the inner compartment locks.
Authorization & Requirements
- Authorization: Master Code “MA1”, Time Code “TC1”
- Requirement: System status “Unlocked” (door locks and door bolt open)
Procedure: Setting the Maximum Open Period
To set the Maximum Open Period, proceed as follows:
1. Wake up display (if necessary) and access menu. | ||
2. Select and confirm the menu option “Settings”. | ||
3. Select and confirm menu option “Settings Lock 1”. | ||
4. Enter and confirm Master Code of lock 1. | ||
5. If the function Maximum Open Period is disabled, select and confirm the menu option “Settings L1 Other”. | ||
6. Select and confirm menu option “Other L1 Max. Open Period” or “Settings S1 Max. Open Period”. | ||
7. Enter and confirm desired Maximum Open Period (format: mm.ss). | ||
The setting is stored. The input unit returns to the menu option “Settings S1 Max. Open Period”. You can now configure other settings or return to the standard mode display. | ||