The function Maximum Open Period allows you to determine how long the door can remain open until a forced closure is triggered. As soon as the Maximum Open Period has elapsed, an intermittent beep sounds when the door locks are open until the system is secured (boltwork closes).
– Setting range of Maximum Open Period [mm:ss]:
00:00 Maximum Open Period disabled
00:01 to 99:59 1 second to 99 minutes and 59 seconds
– On delivery, the Maximum Open Period is disabled (setting “00:00”)
– The Maximum Open Period is available only in the settings for lock 1 and is valid for the entire locking system.
– The setting is taken over with the next opening only.
– The Maximum Open Period does not apply to the inner compartment locks.
Authorization: Master Code “MA1”, Time Code “TC1”
Requirement: System status “Unlocked” (door locks and door bolt open)
To set the Maximum Open Period, proceed as follows:
1. Wake up display (if necessary) and access menu. | ||
2. Select and confirm the menu option “Settings”. | ||
3. Select and confirm menu option “Settings Lock 1”. | ||
4. Enter and confirm Master Code of lock 1. | ||
5. If the function Maximum Open Period is disabled, select and confirm the menu option “Settings L1 Other”. | ||
6. Select and confirm menu option “Other L1 Max. Open Period” or “Settings S1 Max. Open Period”. | ||
7. Enter and confirm desired Maximum Open Period (format: mm.ss). | ||
The setting is stored. The input unit returns to the menu option “Settings S1 Max. Open Period”. You can now configure other settings or return to the standard mode display. | ||