The Wrong Try Penalty occurs when a User inputs a credential incorrectly 4 times in a row. The penalty period is for 5 minutes, within that time no safe lock connected to the Keypad will open. All menu access and command inputs on the Keypad will also be locked for 5 minutes. Once the 5-minute penalty is over, 2 consecutive incorrect credential inputs will initiate another 5-minute penalty. The Wrong Try Penalty does not expire. This penalty cycle will not be cleared until the lock is successfully opened. For Display Keypads, 2 short low beeps and 2 short red flashes will repeat every 10 seconds to signify the penalty is in effect. The time will count down on the screen. During this penalty the Keypad will respond to any key with 2 short low beeps and 2 red flashes. When the Wrong Try Penalty is over, the LED will flash green twice and the keypad will produce 2 high beeps. For Non-Display Keypads, 2 short low beeps and 2 short red flashes will repeat every 10 seconds to signify the penalty is in effect. During the penalty, the Keypad will respond to any key press with a short low beep. When the Wrong Try Penalty is over, the LED will flash green twice and the keypad will produce 2 high beeps. Note: If power to the Keypad is interrupted and restored during a Wrong Try Penalty, the penalty period will resume with same time remaining. |