Answer The system requires that a lock and keypad be connected through an Install or pairing activity. This can be done before or after the Keypad and Lock have been mounted to the safe. To facilitate test opening, physical fit placement, it is recommended that you physically mount the Keypad and Lock prior to setting up the system. Refer to the Safe Lock Installation Guide for detailed instruction on the physical mounting of the Lock and Keypad. (7034.1121) For 702 Keypads, there are two options for performing the Install process; The Standard Install Process or Install with a Preconfigured User. Standard Install Process Note: Before Installation, the Master Combination change is required. Follow these steps to change the Master Combination: - Push any key to wake up the system in factory mode – it will beep and display the red function indicator light for 10 seconds. While the red LED is illuminated, the system is awake, and the “1” key will open the lock, or the keypad is ready process “#” set-up commands
- With the system awake, enter the following to change the Master Combination:
i. The pound sign (#) followed by the number 52 ii. Enter the default Master ID and Master Combination [00 12345678] iii. Enter the Master ID and a new, unique Master Combination [00 _ _ _ _ _ _ _ _ ] iv. Confirm the Master ID and new Master Combination by entering them again [00 _ _ _ _ _ _ _ _ ] v. Press the <return key> (←) If successful, the keypad will respond with 3 high beeps and 3 green LED flashes.
Follow these steps to “INSTALL” (logically, electronically pair) a safe lock to a non-OLED Display Keypad: - Push any key to wake up the system in factory mode – it will beep and display the red function indicator light for 10 seconds. While the red LED is illuminated, the system is awake, and the “1” key will open the lock, or the keypad is ready process “#” set-up commands.
- a) Press 1 to test the opening of the lock, OR
b) With the system awake, enter the following: i. The pound sign (#) followed by the number 22 ii. The Master ID and Master Combination [00 _ _ _ _ _ _ _ _ ] iii. Press the <return key> (←) - The lock is now installed (paired with the keypad). 3 high beeps and 3 green LED flashes will occur to signal that the lock is now Installed (paired with the keypad).
Note: Once “Installed”, there is no need to “wake up” the system before another intended command sequence.
Note: Once “Installed”, there is no need to “wake up” the system before another intended sequence. Managers and Standard users will be required to change their combination upon first use. Install with a Preconfigured User Using the Install with preconfigured users offers a short cut which auto-executes Master Combination Change, the install command, and adds a Manager (user ID 01) all with one command sequence. This short cut can only be executed under specific conditions: - The Keypad and Lock are not currently installed. (The lock has not been installed or has been reset.)
- User 01 is not currently assigned to a user.
- Master User must still have the factory default combination.
This short cut is recommended when the system will be used in these conditions: - System Combination Length set to default of 6 characters.
- User with ID 01 will be a “Manager User” with “Open” and “Audit Capabilities”
- New user combination will be 123456 and should be changed upon first use.
Note: If the system combination length is changed, the user combination must be reset to accommodate the correct character length. Follow these steps to “INSTALL” (logically, electronically pair) a safe lock with a Preconfigured User to a non-OLED Display Keypad: 1. Push any key to wake up the system in factory mode- it will beep and display the red function indicator light for 10 seconds. The system is awake and the “1” key will open the lock, or the keypad is ready to process “#” set-up commands. 2. a) Press 1 to test the opening of the lock OR b) With the system awake, do the following: i. Enter the pound sign (#) followed by the number 50. The keypad will respond with 3 high beeps and 3 green LED flashes. ii. Press a key to wake the keypad again. The keypad will produce a beep and the red LED will illuminate, indicating you must change your combination. Enter the pound sign (#) followed by the number 52, the default Master ID and Combination [00 12345678], the Master ID and a new Combination [00 _ _ _ _ _ _ _ _], the Master ID and the new Combination (to confirm the new combo) [00 _ _ _ _ _ _ _ _], then press the <return key> (←). The keypad will respond with 3 high beeps and 3 green LED flashes. iii. The keypad will beep and display the red function indicator light for 10 seconds. During this 10-second period, press the pound sign (#) followed by the number 22, the Master ID and new Combination [00 _ _ _ _ _ _ _ _], then press the <return key>(←). The keypad will respond with 3 high beeps and 3 green LED flashes. The lock is now Installed (paired with the keypad) and User 01 has been added. The Keypad will beep three times with a green LED. To recap, the total keystroke and keypad feedback sequence is as follows: <return key>+ #50 (3 Green Beeps and Flashes) (Long Red LED) + <return key>+ #52 + 00 (ID) + 12345678 (Combo) + 00 (ID) + [New 8-digit Combo] + 00 (ID) + [New 8-digit Combo] + <return key> (3 Green Beeps and Flashes) (Long Red LED) + #22 + 00 (ID) + [8-digit Combo] +<return key> (3 Green Beeps and Flashes) Note: Manager and Standard users should change their combinations before use, though it is not required with the default system settings. |