The function of Remote Lock allows you to determine whether remote locking can be triggered (enabled) via a remote locking contact connected to the corresponding input of the I/O-Box (by default input 1) or not (function disabled).
– Remote Lock is disabled on delivery.
– If your system does not have an I/O-Box or IP-Box, this function has no effect.
– The function Remote Lock can only be enabled or disabled in the settings for lock 1 and is valid for the entire locking system.
– As standard the Remote Lock function is monitored against sabotage. This setting may only be changed via the AS384 Management-Suite Software.
– The resistive circuit for sabotage surveillance, e.g. when connecting to a hazard alert, is described in the installation instructions.
AS384 Management-Suite Software
In Extended Mode of the locking system, the AS384 Management-Suite Software can be used to assign the function Remote Lock to an input other than 1.
Authorization: Master Code “MA1”
Requirement: System status “Unlocked” (door locks and door bolt open)
To enable or disable the Remote Lock function, proceed as follows:
| 1. Wake up display (if necessary) and access menu. | ||
2. Select and confirm the menu option “Settings”. | ||
3. Select and confirm menu option “Settings Lock 1”. | ||
4. Enter and confirm Master Code of lock 1. | ||
5. If the function Remote Lock is disabled, select and confirm the menu option “Settings L1 Other”. | ||
6. Select and confirm menu option “Other L1 Remote Lock” or “Settings S1 Remote Lock”. | ||
7. Select and confirm desired setting. | ||
The selected setting is stored. The input unit returns to the menu option “Settings S1 Remote Lock”. You can now configure other settings or return to the standard mode display. | ||