The function Time Lock Delay is used to set the Time Lock Delay, which appears as the default value in the activation dialog Time Lock Delay (see section 4.8 "Enabling a Time Lock Delay"). The default value can be changed by the user in the activation dialog and is then stored as a new default value for the next Time Lock Delay.
– Setting range of Time Lock Delay [mmm]:
000 Time Lock Delay disabled
000 to 240 1 minute to 240 minutes
– On delivery, the Time Lock Delay is disabled (0 minutes).
– The Time Lock Delay can only be defi ned in the settings for lock 1 and is valid for the entire locking system.
Authorization: Master Code “MA1”, Time Code “TC1”
Requirement: System status “Unlocked” (door locks and door bolt open)
System status “Secured” (door locks and door lock closed)
To set the Time Lock Delay time, proceed as follows:
1. Wake up display (if necessary) and access menu. | ||
2. Select and confirm the menu option “Settings”. | ||
3. Select and confirm menu option “Settings Lock 1”. | ||
4. Enter and confirm Master Code (or Time Code) of lock 1. | ||
5. If the Time Lock Delay function is disabled, select and confi rm the menu option “Settings L1 Other”. | ||
6. Select and confirm menu option “Other L1 Delay Time Lock” or “Settings L1 Delay Time Lock”. | ||
7. Set and confirm desired Fast Locking period. | ||
The setting is stored. The input unit returns to the menu option “Settings L1 Delay Time Lock”. You can now configure other settings or return to the standard mode display. | ||