The function Fast Locking allows you to specify the default value for the Fast Locking time that appears in the Fast Locking activation dialog (see section 4.7 "Enabling Fast Locking"). The default value can be changed by the user in the activation dialog and is then stored as a new default value for the next Fast Locking process.
– Setting range of Fast Locking [hhh:mm]:
000:00 Fast Locking disabled
000:01 to 144:00 1 minute to 144 hours
– On delivery, the Fast Locking is deactivated.
– The standard value for the Fast Locking period can only be defined in the settings for lock 1 and is valid for the entire locking system.
Authorization: Master Code “MA1”, Time Code “TC1”
Requirement: System status “Unlocked” (door locks and door bolt open)
System status “Secured” (door locks and door lock closed)
To set or change the Fast Locking period, proceed as follows:
1. Wake up display (if necessary) and access menu. | ||
2. Select and confirm the menu option “Settings”. | ||
3. Select and confirm menu option “Settings Lock 1”. | ||
4. Enter and confirm Master Code (or Time Code) of lock 1. | ||
5. If the Fast Locking function is disabled, select and confirm the menu option “Settings L1 Other”. | ||
6. Select and confirm menu option “Other L1 Imm. Time Lock” or ” Settings L1 Imm. Time Lock”. | ||
The setting is stored. The input unit returns to the menu option “Settings L1 Imm. Time Lock”. You can now configure other settings or return to the standard mode | ||