With the function Confirmation Window, you can prevent the automatic opening of the respective lock (door lock 1, last door lock (with Partial Locking) or inner compartment lock) after an Opening Delay has elapsed.
If the Confirmation Window is activated (time 00.00), a valid Opening Code must be entered again within the specified time after expiry of the Opening Delay. If a valid Opening Code is not entered in the Confirmation Window, the opening is automatically cancelled.
– Setting range Confirmation Window [mm:ss]:
00:00 Confirmation Window disabled
00:01 to 99:59 1 second to 99 minutes and 59 seconds
– The Confirmation Window is disabled (set to “00:00”) on delivery.
– The Confirmation Window can be defi ned for door lock 1, the last door lock (only with activated Partial Locking), as well as all inner compartment locks.
Authorization: Master Code, Time Code
Requirement: System status “Unlocked” (door locks and door bolt open)
To set or disable the Confirmation Window, proceed as follows:
| 1. Wake up display (if necessary) and access menu. | ||
| 2. Select and confirm the menu option “Time Functions” | ||
| 3. Select and confirm menu option time functions of the desired lock (e.g. time functions lock 1). | ||
| 4. Enter and confirm Master Code (or Time Code) of the selected lock. | ||
| 5. If the Confirmation Window is disabled, select and confirm the menu option “Time Functions L1 Other”. | ||
| 6. Select and confirm menu option “Other L1 Confirmation wind.” or “Time Functions L1 Confirmation wind.”. | ||
7. Enter and confi rm confirmation period (mm.ss). Note: If you want to disable the Confirmation Window, enter “00.00”. | ||
The setting is stored. The input unit returns to the menu option “Time Functions L1 Confirmation wind.”. You can now configure other time functions or return to the standard mode display. | ||