The function Opening Delay allows you to define how long the opening of the respective lock (door lock 1, last door lock (with Partial Locking) or inner compartment lock) is delayed after entering a valid code or after entering the second valid Opening Code in Dual Mode mode.
– Setting range time delay [mm:ss]:
00:00 Opening Delay disabled
00:01 to 99:59 1 second to 99 minutes and 59 seconds
– The Opening Delay is disabled (set to “00:00”) on delivery.
– The Opening Delay can be defined for door lock 1, the last door lock (only with activated Partial Locking), as well as all inner compartment locks.
– If the code entry is finished when opening a safe compartment with opening delay before the locking period starts but the opening delay ends after the locking period has started the lock opens. This does not apply if a confirmation window is configured. In this case the lock cannot be opened during an ongoing locking period.
AS384 AS384 Management-Suite Software
In Extended Mode of the locking system with the code format “PIN only” or “ID+PIN”, the AS384 Management-Suite Software can also be used to define a Time-Dependent Opening Delay. During the specified time, the Time-Dependent Opening Delay overrides the default Opening Delay.
In Extended Mode of the locking system with code format “ID+PIN”, the AS384 ManagementSuite Software can also be used to define a Code-Related Opening Delay. The code-related Opening Delay overrides the default Opening Delay.
Authorization: Master Code, Time Code
Requirement: System status “Unlocked” (door locks and door bolt open)
To set or disable the Opening Delay, proceed as follows:
| 1. Wake up display (if necessary) and access menu. | ||
| 2. Select and confirm the menu option “Time Functions” | ||
| 3. Select and confirm menu option time functions of the desired lock (e.g. time functions lock 1). | ||
| 4. Enter and confirm Master Code (or Time Code) of the selected lock. | ||
| 5. If the Opening Delay is disabled, select and confirm the menu option “Time Functions L1 Other” | ||
| 6. Select and confirm menu option “Other L1 Time Delay” or “Time Functions L1 Time Delay”. | ||
| 7. Enter and confirm Opening Delay (mm.ss). Note: If you want to disable the Opening Delay, enter “00.00”. | ||
The setting is stored. The input unit returns to the menu option “Time Functions L1 Time Delay”. You can now configure other time functions or return to the standard mode display. | ||