The Partial Locking function allows the definition of time windows during which the door locks may be partially locked. If a Partial Locking is active, only the last lock (with 2 locks: door lock 2, with 3 locks: door lock 3) is locked when the container door is locked.
– A maximum of 28 Partial Locking periods can be set.
– Setting range for Partial Locking: 1 minute to 6 days, 23 hours, and 45 minutes.
– Defined Time Lock Overrides are stored in the list in chronological order.
– Locking period interruptions do not expire.
Authorization: Master Code “MA1”, Time Code “TC1”
Requirement: System status “Unlocked” (door locks and door bolt open)
To set, change, or delete an existing Partial Locking Period, proceed as follows:
| 1. Wake up display (if necessary) and access menu | ||
| 2. Select and confirm the menu option “Time Functions” | ||
| 3. Select and confirm menu option “Time Functions Lock 1” | ||
| 4. Enter and confirm Master Code (or Time Code) of lock 1. | ||
| To Set a New Partial Locking Period, continue with step 5. To change an existing Partial Locking Period, continue with step 10. To delete an existing Partial Locking Period, continue with step 15. | ||
Setting New Partial Locking Periods | ||
| 5. If no Partial Locking Periods have been configured yet, select and confirm the menu option “Time Functions L1 Other”. | ||
| 6. Select and confirm menu option “Other L1 Partial Locking” or “Time Functions L1 Partial Locking”. |
|
|
| 7. Select and confirm next unassigned Partial Locking Period (e.g. “Partial Locking 02”). | ||
| 8. Set and confirm date and time for the start of the selected Partial Locking Period. | ||
| 9. Set and confirm date and time for the end of the selected Partial Locking Period. | ||
|
The Partial Locking Period is stored. The input unit returns to the menu option “Time Functions L1 Partial Locking”. You can now configure additional Partial Locking Periods (repeat steps 5 to 9) or return to the standard mode display. |
|
|
Changing Partial Locking Periods | ||
| 10. Select and confirm menu option “Time Functions L1 Partial Locking”. | ||
| 11. Select and confirm the Partial Locking Period you wish to change. | ||
| 12. Select and confirm menu option “Change” | ||
| 13. Set and confirm new week day and/or new time for the start of the selected Partial Locking Period. | ||
| 14. Set and confirm new week day and/or new time for the end of the selected Partial Locking Period. | ||
|
The changed Partial Locking Period is stored. The input unit returns to the menu option “Time Functions L1 Partial Locking”. You can now change additional Partial Locking Periods (repeat steps 10 to 14) or return to the standard mode display. |
|
|
Deleting Partial Locking Periods | ||
| 15. Select and confirm menu option “Time functions Partial Locking” | ||
| 16. Select and confirm the Partial Locking Period you wish to delete. | ||
| 17. Select and confirm menu option “Delete” | ||
| 18. Confirm deletion | ||
|
The changed Partial Locking Period is deleted. The input unit returns to the menu option “Time Functions L1 Partial Locking”. You can now delete additional Partial Locking Periods (repeat steps 15 to 18) or return to the standard mode display. |
||