The function Time Lock Override allows the definition of time windows during which locking periods are interrupted and the locks can be opened.
– A maximum of 8 Time Lock Overrides can be set.
– Setting range of a Time Lock Override: 1 to 144 hours.
– Defined Time Lock Overrides are stored in the list in chronological order.
– No Time Lock Overrides can be created for the past.
– Once a Time Lock Override has elapsed, it is deleted, and the list with the defined Time Lock Overrides is chronologically updated.
– Once a locking period has started no Time Lock Overrides can be set, changed or deleted.
Authorization: Master Code “MA1”, Time Code “TC1”
Requirement: System status “Unlocked” (door locks and door bolt open)
To set new Time Lock Overrides, proceed as follows:
| 1. Wake up display (if necessary) and access menu. | ||
| 2. Select and confirm the menu option “Time Functions”. | ||
| 3. Select and confirm menu option “Time Functions Lock 1”. | ||
| 4. Enter and confirm Master Code (or Time Code) of lock 1. | ||
| To Set a New Time Lock Override, continue with step 5. To Change an Existing Time Lock Override, continue with step 10. To Delete an Existing Time Lock Override, continue with step 15. | ||
| 5. If no Time Lock Overrides have been configured yet, select and confirm the menu option “Time Functions L1 Other”. | ||
| 6. Select and confi rm menu option “Other L1 Time Lock Overr.” or “Time Functions L1 Time Lock Overr.”. | ||
| If Time Lock Overrides have already been confi gured, the display with the data “Time Lock Interrupt. 01”. Otherwise, the display of the “Time Lock Interrupt. 01 appears without data. | ||
| 7. Select and confirm the next Time Lock Override (e.g. “Time Lock Interrupt. 02”). | ||
| 8. Set and confirm date and time for the start of the selected Time Lock Override. | ||
| 9. Set and confirm date and time for the end of the selected Time Lock Override. | ||
The Time Lock Override is stored. The input unit returns to the menu option “Time Functions L1 Time Lock Overr.”. You can now configure additional Time Lock Overrides (repeat steps 5 to 9) or return to the standard mode display. | ||
Changing Time Lock Overrides | ||
| 10. Select and confirm menu option “Time Functions L1 Time Lock Overr.”. | ||
| 11. Select and confirm the Time Lock Override you want to change. | ||
| 12. Select and confirm menu option “Change”. | ||
| 13. Set and confirm new date and/or new time for the start of the selected Time Lock Override. | ||
| 14. Set and confirm new date and/or new time for the end of the selected Time Lock Override. | ||
The changed Time Lock Override is stored. The input unit returns to the menu option “Time Functions L1 Time Lock Overr.”. You can now configure additional Time Lock Overrides (repeat steps 10 to 14) or return to the standard mode display. | ||
Deleting Time Lock Overrides | ||
| 15. Select and confirm menu option “Time Functions L1 Time Lock Overr.”. | ||
| 16. Select and confirm the Time Lock Override you wish to change. | ||
| 17. Select and confirm menu option “Delete”. | ||
| 18. Confirm deletion. | ||
The Time Lock Override is deleted. The input unit returns to the menu option “Time Functions L1 Time Lock Overr.”. You can now delete additional Time Lock Overrides (repeat steps 15 to 18) or return to the standard mode display. | ||