The function Yearly Locking Period allows the definition of locking periods for holidays recurring each year at the same date and time.
– A maximum of 28 Yearly Locking periods can be set.
– Setting range year locking period: 1 Minute to 34 days 23 hours and 45 minutes.
– Yearly Locking Periods do not expire. If a Yearly Locking Period is no longer needed (e.g. an eliminated holiday), it must be deleted.
– If the final date of a Yearly Locking Period is the last day of February, we recommend setting it to the 29th of February. Thus, leap years will automatically be included.
– Yearly Locking Periods can only be changed or deleted as long as they have not started.
Authorization: Master Code “MA1”, Time Code “TC1”
Requirement: System status “Unlocked” (door locks and door bolt open)
To set, modify, or delete existing Yearly Locking Periods, proceed as follows:
| 1. Wake up display (if necessary) and access menu. | ||
| 2. Select and confirm the menu option “Time Functions”. | ||
| 3. Select and confirm time function lock 1. | ||
| 4. Enter and confirm Master Code (or Time Code) of lock 1. | ||
| To Set a New Yearly Locking Period, continue with step 5. To Change an existing Yearly Locking Period, continue with step 10. To Delete an Existing Yearly Locking Period, continue with step 15. | ||
Setting a New Yearly Locking Period | ||
| 5. If no Yearly Locking Periods have been confi gured yet, select and confirm the menu option “Time Functions L1 Other”. | ||
| 6. Select and confirm menu option “Other L1 Yearly” or “Time Functions L1 Yearly”. |
|
|
| 7. Select and confirm next unassigned Yearly Locking Period (e.g. Yearly Locking Period 02). | ||
| 8. Set the date (day and month) and time for the start of the selected Yearly Locking Period and confirm. | ||
| 9. Set the date (day and month) and time for the end of the selected Yearly Locking Period and confirm. | ||
|
The Yearly Locking Period is stored. The input unit returns to the menu option “Time Functions L1 Yearly”. You can now configure additional Yearly Locking Periods (repeat steps 6 to 9) or return to the standard mode display. |
||
Changing a Yearly Locking Period | ||
| 10. Select and confirm menu option “Time Functions L1 Yearly”. | ||
| 11. Select and confirm desired Yearly Locking Period. | ||
| 12. Select and confirm menu option “Change”. | ||
| 13. Set and confirm new date and/or new time for the start of the selected Yearly Locking Period. | ||
| 14. Set and confi rm new date and/or new time for the end of the selected Yearly Locking Period. | ||
|
The changed Holiday Locking Period is stored. The input unit returns to the menu option “Time Functions L1 Yearly”. You can now configure additional Yearly Locking Periods (repeat steps 10 to 14) or return to the standard mode display. |
||
Deleting a Yearly Locking Period | ||
| 15. Select and confirm menu option “Time Functions L1 Yearly”. | ||
| 16. Select and confirm the Yearly Locking Period you want to delete. | ||
| 17. Select and confirm menu option “Delete”. | ||
| 18. Confirm deletion. | ||
|