| Settings | Paxos Advanced Standalond Mode | Paxos Advanced Extended <ode With AS384 Management-Suite Software | |
| (PIN Only) | (PIN Only) | (ID+PIN) | |
| Code Functions | |||
| Master Code | ✓ | ✓ | ✓ Several Master Codes |
| Opening Codes a-z and 27-95 | ✓ | ✓ | ✓ |
| AND Code a and b | ✓ | ✓ | ✓ |
| Mutation Code | ✓ | ✓ | ✓ Several Mutation Codes |
| Time Code | ✓ | ✓ | ✓ Multiple Time Codes |
| Net Codes | (✓) | ✓ | ✓ Multiple Net Codes |
| Code Profiles | ✓ | ||
| Code Profile Groups | ✓ | ✓ | |
| Code Type PIN | ✓ | ✓ | |
| Code Type ID+PIN | ✓ | ||
| Time Penalties | ✓ | ✓ | ✓ |
| Time Fuctions Lock 1 (Valid for the Entire locking System) | |||
| Date/Time | ✓ | ✓ | ✓ |
| Holiday Locking Period | ✓ | ✓ | ✓ |
| Yearly Locking Period | ✓ | ✓ | ✓ |
| Weekly Locking Period | ✓ | ✓ | ✓ |
| Time Lock Override | ✓ | ✓ | ✓ |
| Partial Locking | ✓ | ✓ | ✓ |
| Opening Delay | ✓ | ✓ | ✓ |
| Duress Delay | ✓ | ✓ | ✓ |
| Confirmation Window | ✓ | ✓ | ✓ |
| Return Time Lock | ✓ | ✓ | ✓ |
| Time-Controlled Delaey Times | ✓ | ✓ | |
| Summer/Winter Time Changeover | ✓ | ✓ | ✓ |
| Manual or automatic time zone rules | |||
| Synchronization with PC Time | ✓ | ✓ | |
| Time Functions Last Lock (values can be set, if partial locking is activated) | |||
| Opening Delay | ✓ | ✓ | ✓ |
| Duress Delay | ✓ | ✓ | ✓ |
| Confirmation Window | ✓ | ✓ | ✓ |
| Return Time Lock | ✓ | ✓ | ✓ |
| Settings Lock 1 (Valid for the Entire Locking System) | |||
| Duration Fast Locking | ✓ | ✓ | ✓ |
| Duration Time Lock Delay | ✓ | ✓ | ✓ |
| Date/Time Format | ✓ | ✓ | ✓ |
| Locking Mode | ✓ | ✓ | ✓ |
| Remote Lock | ✓ | ✓ | ✓ |
| Parallel Mode | ✓ | ✓ | ✓ |
| Set Duress Code | ✓ | ✓ | ✓ |
| Dual Mode | ✓ | ✓ | ✓ |
| Maximum Open Period | ✓ | ✓ | ✓ |
| Settings Input Unit | |||
| Dialog Language | ✓ | ✓* | ✓* |
| Volume | ✓ | ✓* | ✓* |
| Lighting | ✓ | ✓* | ✓* |
| Contrast | ✓ | ✓* | ✓* |
| Battery Compartment | ✓ | ✓* | ✓* |
| System Settings | |||
| Maximum Door Openinig Time | ✓ | ✓ | ✓ |
| Count Direction Opening and Duress Delay Time | ✓ | ✓ | |
| Count direction Confirmation Window | ✓ | ✓ | |
| Count Direction Return Time Window | ✓ | ✓ | |
| Count Direction Penalty Time | ✓ | ✓ | |
| Duress Settings | |||
| Use Duress Alarm | ✓ | ✓ | ✓ |
| Set Code Position for Duress Alarm | ✓ | ✓ | |
| Inputs/Outputs I/O-Box | |||
| Configure Inputs | ✓ | ✓ | |
| Configure Outputs | ✓ | ✓ | |
| Audit | |||
| Reading the Audit | ✓ | ✓ | |
| Export Lock Information | ✓ | ✓ | |
| Inport Audits | ✓ | ✓ | |
*only adjustable on input unit