Authorization: Valid Opening Code or two valid Opening Codes for Dual Mode
Requirement: System status “Secured” (door locks and door bolt closed)
To open the door locks (e.g. safe door with 2 locks) proceed as follows:
The process for opening the door locks is dependent on the configuration of the system. In the following opening sequence, displays and entries that appear only when the system is accordingly configured are shown with a grey background.
| 1. Wake up display (if necessary) and access the menu. | ||
2. Confirm menu option “Open”. | ||
| Open Door Lock 1 | ||
3. Activate code input (door lock 1). Note: This step is not mandatory. You can also start with code entry for door lock 1, the code input window will appear automatically (see point 4). | ||
| 4. Enter and confi rm a valid Opening Code for door lock 1. | ||
This code entry window appears only if Dual Mode is enabled for door lock 1, or the And-codes are enabled (OCa1& or OCa2&) for the Opening Codes OCa1 and OCb2. 5. Enter a valid second Opening Code for door lock 1 and | ||
| If an Opening Delay has been defined for door lock 1, the Opening Delay window appears. The time remaining until the lock can be opened is displayed. Note: In extended mode, the opening delay period can be set to “count down”, “count up” or “off (do not count)” via the AS384 Management-Suite Software. | ||
If the Confirmation function is activated for door lock 1, the Confirmation Window appears. a new valid Opening Code of door lock 1 must be entered within the displayed confirmation time. 6. Enter and confirm a valid Opening Code (Confirmation | ||
| Door lock 1 opens. Door lock 1 is opened. | ||
| Opening door lock 2 | ||
| 7. Enter and confirm a valid Opening Code for door lock 2. | ||
This code entry window appears only if Dual Mode is enabled for door lock 2, or the And-codes are enabled (OCa1& or OCa2&) for the Opening Codes OCa1 and OCb2.
| ||
| If the Confirmation function is activated for door lock 2, the Confirmation Window appears. A new valid Opening Code of door lock 2 must be entered within the displayed confirmation time. | ||
| 9. Enter and confirm a valid Opening Code (Confirmation Code) for door lock 2. | ||
| Door lock 2 opens. Door lock 2 is opened. | ||
| All door locks are open. The door bolt must be opened within one minute, otherwise the locks will automatically close again. | ||
| 10. Open door bolt. | ||
| The container door is unlocked (door locks open and boltwork unblocked). | ||