MANAGER COMMANDS
NOTE: If “Dual Mode and [User + Manager] to access Manager Menu” was selected during lock set-up, each command below requires entering User combination followed by the Manager combination and hold down last digit of Manager combination until Lock double beeps. Then release and the LED stays on.
COMMAND 1
Activate User
NOTE: Only Users added during Lock Setup will be available to the Manager for activation.
- Enter Manager combination and hold down last digit of combination until Lock double signals release and the LED stays on.
- PRESS 1.
- Enter User number (1- 9).
- Enter the NEW User combination.
- Re-enter the NEW User combination to confirm. User combination is now active.
Reinstate User
- Enter Manager combination and hold down last digit of combination until Lock double signals release and the LED stays on.
- PRESS 1.
- Enter User number (1- 9). User is reinstated.
COMMAND 2
Disable User
- Enter Manager combination and hold down last digit of combination until Lock double signals release and the LED stays on.
- PRESS 2.
- Enter User number (1- 9). User is temporarily disabled. The User combination is saved and will be valid once reinstated.
COMMAND 3
Delete User
- Enter Manager combination and hold down last digit of combination until Lock double signals release and the LED stays on.
- PRESS 3.
- Enter User number (1- 9). User is deleted.
COMMAND 7
Audit Lock (ComboGard Pro auditing software, AuditView or LgView3X, and a LA GARD Interface Adapter are required)
To audit the Lock using ComboGard Pro AuditView Software, you can also refer to ComboGard Pro AuditView User Instructions (786.0310).
Start the Auditing Software Program:
- Plug the USB or Serial Interface Adapter into an available port on the PC.
- Plug the appropriate audit cable for the Entry Device into the USB or Serial Interface Adapter.
- Start auditing software program.
- From the auditing software, select the Configuration menu on the Menu bar.
- Select the appropriate COM port from the list
Audit the Lock:
- Connect the audit cable to the Entry Device.
- Enter Manager combination and hold down last digit of combination until Lock double signals release and the LED stays on.
- Click the safe icon button or select Start Acquisition from the Actions menu on the Menu bar.
- PRESS 7. The Entry Device will beep once and the audit records will be transmitted to the PC for display on the screen.
- Once the audit is complete, disconnect the audit cable from the Entry Device.
Check User Status
- Enter Manager combination and hold down last digit of combination until Lock double signals release and the LED stays on.
- PRESS AND HOLD 7 until double signals twice.
- Enter the User ID number (1 to 9)
Lock response:
• One beep – User is active
• Two beeps – User is disabled
• Three beeps – User is deleted
• One long beep – User is blocked - To exit PRESS 0
COMMAND 9
Set or Change Time Delay Values
NOTE: If Time Delay is active, it may only be deactivated or the Delay value “decreased” during an Open Period.
- Enter Manager combination and hold down last digit of combination until Lock double signals release and the LED stays on.
- PRESS 9.
- Enter two-digit Delay Period value (00 to 99 minutes) followed by the two-digit Open Period value (00 to 19 minutes).
NOTE: Entering “0000” will deactivate the Time Delay Feature.
- Re-enter the Delay and Open Period values to confirm.