Super Master Reset in ComboGard Pro 39E Electronic Combination Lock
SMR will reset the lock back to factory state, but the SM code remains unchanged. The default code of 5-5-5-5-5-5- 5-5 must be changed before the Manager default code is changed or the Super Master Reset function will be permanently lost.
Process is as follows:
- Action - Press and hold [0] key for 3 seconds
- Result – Lock beeps twice and the LED remains ON throughout the entire process
- Action – Enter default code of 5-5-5-5-5-5-5-5. Press and hold last digit until the unit gives a double beep.
- Result – Command Menu access is granted.
SMR has only 2 Command options available:
- If press [0] = Change Code, (1 time use)
- Enter current default Super Master code of 5-5-5-5-5-5-5-5
- Enter new Super Master code (ex. 8-8-8-8-8-8-8-8) then double beep.
- Enter new Super Master code again to confirm (ex. 8-8-8-8-8-8-8-8) then double beep the SMR code is set.
NOTE: Once the default code is changed to a new code the code can never be changed. A reset box must be used to reset.
- If press [8] = Reset the Lock
- Lock will signal a long beep to indicate it was reset
- If any other key is pressed then the lock beeps 3 times and the operation is ended.