LOCK OPERATING CONVENTIONS
If a mistake is made while entering keystrokes, wait thirty (30) seconds and repeat operation.
To access lock commands, enter combination and hold down the last digit until Lock double signals release and the LED stays on.
In Dual Mode, two combinations are required to operate the Lock.
NOTE:
In Dual Mode, two combinations are required to open the lock. Manager Commands 1,2,3,7 and 9 can be performed using the Manager combination alone.
In Dual Mode and [User + Manager], two combinations are required for all lock functions except to Change Combination. A valid User combination must be entered first, followed by the Manager combination to access Manager Commands 1,2,3,7 and 9.
Lock must be opened within 4 seconds once a valid combination has been entered.
To open a container with a Swing Bolt Lock, turn the container handle to the open position and open the door.
To open a container with a Dead or Spring Bolt Lock, turn the keypad or dial to retract the bolt and open the door.
When closing a container, verify that it has been secured.