Programmable Lock Feature modes in ComboGard Pro 39E Electronic Combination Lock
Updated
PROGRAMMABLE LOCK FEATURES MODES (Multiple Modes may be selected.)
Silent Alarm (Alarm Box Required - P/N 2789NC) If enabled, this option will send a signal to an outside alarm system through the LA GARD Alarm Box.
Dual Mode If enabled, two combinations are required to open the lock. All other manager functions can be performed using the Manager combination alone.
Dual Mode and [User + Manager] to access Manager Menu If enabled, two combinations are required to perform all lock functions and is only available on locks with 39E code level .669 or higher. Selection of “Dual Mode and [User + Manager] to access Manager Menu” can only be done using the ComboGard Pro Setup Software v.5.2.0.116 or higher. If this mode is selected in the software but sent to a lock with incompatible (older) firmware code, the user will receive an error message and the lock will not be programmed.
Time Delay Override If enabled, User 9 can override delay period. User 9 must be active.