How to do Super Master Reset in LA GARD Basic - Electronic Combination Safe Lock?
- 8 Digit code – default code 5-5-5-5-5-5-5-5 [consistent with other LA GARD locks]
- If the default code is not changed before Manager changes his or her code then the SMR option will be lost, unless hard reset of the lock is performed.
- Once set the SMR cannot be changed, unless hard reset.
SMR will reset the lock back to factory state, but SM code remains unchanged. The default code of 5-5-5-5-5-5-5-5 must be changed before the Manager default code is changed or the function will be permanently lost.
Process is as follows:
- Action - Press and hold [0] key for 3 seconds
- Result – Lock beeps twice and the LED is ON, until the process is complete
- Action – default code is entered 5-5-5-5-5-5-5-5 (last digit must be held for 3 seconds)
- Result – Command Menu access is granted.
SMR has only 2 Command options available.
- If press [0] = change code, (1 time use)
- NOTE: once the default code is changed to a new code the code can never be changed. A reset box must be used to reset.
- If press (8) = Reset the lock.