Activation from Factory Mode to Bank Mode
Initialize Lock and Enter Factory Combination
Step Action Power up lock Turn dial CCW until EC is displayed EC Enter 50-25-50 OPR Turn dial CW to open lock and retract bolt Insert Change Key Insert the change key into the lock Extend Bolt Extend the bolt to secure the lock Initialize Bank Mode and Activate SA Key
Step Action Power left Turn dial CCW until £EC appears, then enter 50-25-50 ISA Insert and hold the RED SA KEY in the reader INI Lock is initializing POC Remove the RED SA KEY and pull out the change key OPR Turn dial CW to retract bolt Extend Bolt Extend the bolt to secure the lock
Applies To
Cencon Lock (Swing Bolt)