|
Question How to Retrieve a Cencon change key has been left locked after any process? |
|
Answer Follow the below Steps to Cencon change key has been left locked after any process: 1. Power Up the Lock: Turn the dial to the left. 2. Check Display: If the lock displays "tEC", it means the lock detects the change key inside. 3. Enter Code: If prompted, enter the code and present the key. The lock may display a 4. Wait for LCD to Power Off: Allow the LCD to turn off. 5. Power On the Lock: Turn the dial to the right. 6. Observe Display: The lock will display "G2 → EC". 7. Enter Code: Enter the code provided by your dispatcher or your bank mode combination. 8. Touch Key to Reader: When "IPI" is displayed on the LCD, touch your key to the key reader. 9. Lock Displays "OPr": The lock will now display "OPr". 10. Open Lock and Retrieve Key: Turn the dial to the right, open the lock, and retrieve the 11. Close Container: Close the container, retrieve the close code, and return it to the dispatcher
|